PR60系列40安培微型功率继电器

  • DPST-NO和DPDT配置
  • 符合8毫米爬电距离,4千伏电介质
  • 可提供环氧树脂密封版本
  • UL F级(155℃)标准
, , ,
SKU PR60 Category Tag

产品描述

产品模型

PR60 -2A -5D -F
产品系列
联系类型 2A、2B、2C
线圈电压 见表
线圈引脚规格 F、KF、PF
产品系列 联系类型 线圈电压 线圈引脚规格 图解
PR60 2A 5D F 联系类型:
2B 6D KF 2A:2组常开触点
2C 基金会 2B:2组常闭触点
12D
2C:2组转换联系人
24D
48D 线圈电压:
110D
24D:DC 24V
12A5
24A5: AC 24V 50Hz
24A5
24A6: AC 24V 50/60Hz
120A5
220A5 线圈引脚规格:
F: 线圈针脚规格为6.35×0.8
240A5
KF:线圈针脚规格为4.75×0.5
277A5
PF:线圈引脚规格为PCB引脚
12A6
类型
24A6
120A6
220A6
240A6
277A6
高保护型:在线圈电压后面加上字母 "E"。 例如:PR60-2A-24DF改为PR60-2A-24DEF 线圈引脚规格为4.75×0.5:将 "F "改为 "KF"。 比如说:PR60-2C-24A6F改成PR60-2C-24A6KF
线圈引脚规格为PCB引脚类型:将 "F "改为 "PF"。 比如说:PR60-2C-24A5F改成PR60-2C-24A6PF

联系我们

ArrangementDPST (2 Form A)
DPDT(2 Form C)
RatingsResistive load:
Max. switched power: 1200 W or 11080 VA Max. switched current: 40A (N.O), 3A (N.C.) Max.switchedvoltage:30VDC*or600VAC
*Note: If switching voltage is greater than 30VDC, special precautions must be taken. Please contact
the factory.
Rated Load UL
VDE
Normally open contacts (N.O.)
40A at 277VAC, Resistive, 30k cycles [1][2]
30A at 277VAC, General Use, 100k cycles [1][2] 10A at 600VAC, General Use, 6k cycles [1] 1HP at 120VAC, 100k cycles [1][2]
2.5HP at 240VAC, 100k cycles [1][2]
8FLA / 26LRA at 277/480/600VAC, 30k cycles [1]
Normally open contacts (N.O.), DC Coils only 25.3FLA / 110LRA at 240VAC, 30k cycles [1][2]
Normally closed contacts (N.C.)
3A at 277VAC, General Use, 100k cycles [1][2] 2A at 480VAC, General Use, 6k cycles [1]
1A at 600VAC, General Use, 6k cycles [1] 3FLA / 3LRA at 240VAC, 30k cycles [1] 2FLA / 2LRA at 277/480VAC, 30k cycles [1] 1FLA / 1LRA at 600VAC, 30k cycles [1]
Normally open contacts (N.O.)
20A at 250VAC, Resistive, 50k cycles [2]
Normally closed contacts (N.C.)
3A at 250VAC, Resistive, 50k cycles [2]
MaterialSilver cadmium [1], silver tin oxide [2]
Resistance<50 milliohms initially
(24V, 1A voltage drop method)

一般数据

Operate Time15ms typical
25ms maximum with bounce
Release Time10ms typical
25ms maximum with bounce (with no coil suppression)
Dielectric Strength
(at sea level for 1 min)
1500Vrms contact to contact
4000Vrms contact to coil
2000Vrms between contact sets
Insulation Resistance109 ohms minimum at 500VDC
DropoutDC:Greater than 10%of nominal coil voltage
AC: Greater than 20%of nominal coil voltage
Ambient Temperature Operating
Storage
At nominal coil voltage
DC: -40°C (-40°F) to 85°C (185°F)
AC: -40°C (-40°F) to 65°C (149°F)
-40°C (-40°F) to 105°C (221°F)
Vibration0.062" (1.65mm) DA at 10–55Hz
ShockOperational, 10g for 11ms 1/2 sine pulse (no contact opening > 100usec)
Non-destructive, 100g for 11ms 1/2 sine pulse
EnclosureP.B.T. polyester
TerminalsQuick connect tabs
Note: Allow suitable slack on leads when wiring, and do not subject the terminals to excessive force.
Max. Solvent Temp.80°C (176°F)
Max. Immersion Time30 seconds
Weight86 grams
Packing unit in pcs20 per plastic tray / 100 per carton box

绕组

Power
At Pickup Voltage925mw.DCcoil
(typical)2.6VA AC coil
Max. Continuous5.0Wat20°C(68F)ambient DC oo
Dissipation7.0VA at 20°C(68°F)ambient AC coil
Temperature Rise48C86°Fatnominal coilvoltage,DCcoil 68C(122F)atnominal coi voltage,AC coil
TemperatureMax. 155°C (311°F)
Notes:
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.

继电器订购数据

COIL SPECIFICATIONS – DC CoilORDER NUMBER*
Nominal Coil
VDC
Must Operate
VDC
Max. Continuous
VDC
Nominal Current
mA ± 10%
Coil Resistance
Ohm ± 10%
53.88.0326.715.3PR60–2C–5D
64.510.5272.022PR60–2C–6D
129.020.7140.086PR60–2C–12D
2418.041.868.5350PR60–2C–24D
7836.083.434.51390PR60–2C–48D
11082.5190.515.27255PR60–2C–110D
COIL SPECIFICATIONS – AC CoilORDER NUMBER*
Nominal Coil
VDC
Must Operate
VDC
Max. Continuous
VDC
Nominal Current
mA ± 10%
50Hz Coil Resistance
Ohm ± 10%
60Hz Coil Resistance
Ohm ± 10%
129.615.6340.09.58PR60–2C–12A6
2419.231.2166.04535.7PR60–2C–24A6
12096.0156.033.31125830PR60–2C–120A6
220176.0286.018.238002870PR60–2C–220A6
240192.0312.016.745003800PR60–2C–240A6
277221.6360.114.459604700PR60–2C–277A6
  • 用 “2A “代替 “2C”,表示2个A型联系人。
  • “2A “或 “2C “表示银镉触点。
  • 在 “2A “或 “2C “中加入后缀 “E”,用于银锡氧化物触点。
  • 对于50Hz的线圈,只需添加后缀 “5 “的交流线圈。 (例如:PR60-2C-24A5)。
  • 50/60Hz的线圈加后缀 “6”,只适用于交流线圈。 (例如:PR60-2C-24A6)。
  • 如果是密封版本,请在订单号后面加上后缀 “E”。
  • 对于0.187″ x 0.020″ (4.8mm x 0.5mm)线圈终端,添加后缀 “K”。

机械数据

%文件名%

下载

滚动至顶部

TALK TO OUR EXPERT​

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!
  • 19

    Years of experience

    50+

    Countries & Areas

    500 +

    Customers

    30,000

    ㎡ Manufacturing Factory

    与我们的专家交谈

  • 我们会在12小时内联系您
  • 别担心,我们也讨厌垃圾邮件!
  • 19

    经验年限

    50+

    国家和地区

    500 +

    客户

    30,000

    ㎡ 制造工厂