产品描述
产品模型
PR60 | -2A | -5D | -F | |
产品系列 | ||||
联系类型 | 2A、2B、2C | |||
线圈电压 | 见表 | |||
线圈引脚规格 | F、KF、PF |
产品系列 | 联系类型 | 线圈电压 | 线圈引脚规格 | 图解 |
---|---|---|---|---|
PR60 | 2A | 5D | F | 联系类型: |
2B | 6D | KF | 2A:2组常开触点 | |
2C | 基金会 | 2B:2组常闭触点 | ||
12D | ||||
2C:2组转换联系人 | ||||
24D | ||||
48D | 线圈电压: | |||
110D | ||||
24D:DC 24V | ||||
12A5 | ||||
24A5: AC 24V 50Hz | ||||
24A5 | ||||
24A6: AC 24V 50/60Hz | ||||
120A5 | ||||
220A5 | 线圈引脚规格: | |||
F: 线圈针脚规格为6.35×0.8 | ||||
240A5 | ||||
KF:线圈针脚规格为4.75×0.5 | ||||
277A5 | ||||
PF:线圈引脚规格为PCB引脚 | ||||
12A6 | ||||
类型 | ||||
24A6 | ||||
120A6 | ||||
220A6 | ||||
240A6 | ||||
277A6 | ||||
高保护型:在线圈电压后面加上字母 "E"。 例如:PR60-2A-24DF改为PR60-2A-24DEF 线圈引脚规格为4.75×0.5:将 "F "改为 "KF"。 比如说:PR60-2C-24A6F改成PR60-2C-24A6KF 线圈引脚规格为PCB引脚类型:将 "F "改为 "PF"。 比如说:PR60-2C-24A5F改成PR60-2C-24A6PF |
联系我们
Arrangement | DPST (2 Form A) DPDT(2 Form C) |
Ratings | Resistive load: Max. switched power: 1200 W or 11080 VA Max. switched current: 40A (N.O), 3A (N.C.) Max.switchedvoltage:30VDC*or600VAC *Note: If switching voltage is greater than 30VDC, special precautions must be taken. Please contact the factory. |
Rated Load UL VDE | Normally open contacts (N.O.) 40A at 277VAC, Resistive, 30k cycles [1][2] 30A at 277VAC, General Use, 100k cycles [1][2] 10A at 600VAC, General Use, 6k cycles [1] 1HP at 120VAC, 100k cycles [1][2] 2.5HP at 240VAC, 100k cycles [1][2] 8FLA / 26LRA at 277/480/600VAC, 30k cycles [1] Normally open contacts (N.O.), DC Coils only 25.3FLA / 110LRA at 240VAC, 30k cycles [1][2] Normally closed contacts (N.C.) 3A at 277VAC, General Use, 100k cycles [1][2] 2A at 480VAC, General Use, 6k cycles [1] 1A at 600VAC, General Use, 6k cycles [1] 3FLA / 3LRA at 240VAC, 30k cycles [1] 2FLA / 2LRA at 277/480VAC, 30k cycles [1] 1FLA / 1LRA at 600VAC, 30k cycles [1] Normally open contacts (N.O.) 20A at 250VAC, Resistive, 50k cycles [2] Normally closed contacts (N.C.) 3A at 250VAC, Resistive, 50k cycles [2] |
Material | Silver cadmium [1], silver tin oxide [2] |
Resistance | <50 milliohms initially (24V, 1A voltage drop method) |
一般数据
Operate Time | 15ms typical 25ms maximum with bounce |
Release Time | 10ms typical 25ms maximum with bounce (with no coil suppression) |
Dielectric Strength (at sea level for 1 min) | 1500Vrms contact to contact 4000Vrms contact to coil 2000Vrms between contact sets |
Insulation Resistance | 109 ohms minimum at 500VDC |
Dropout | DC:Greater than 10%of nominal coil voltage AC: Greater than 20%of nominal coil voltage |
Ambient Temperature Operating Storage | At nominal coil voltage DC: -40°C (-40°F) to 85°C (185°F) AC: -40°C (-40°F) to 65°C (149°F) -40°C (-40°F) to 105°C (221°F) |
Vibration | 0.062" (1.65mm) DA at 10–55Hz |
Shock | Operational, 10g for 11ms 1/2 sine pulse (no contact opening > 100usec) Non-destructive, 100g for 11ms 1/2 sine pulse |
Enclosure | P.B.T. polyester |
Terminals | Quick connect tabs Note: Allow suitable slack on leads when wiring, and do not subject the terminals to excessive force. |
Max. Solvent Temp. | 80°C (176°F) |
Max. Immersion Time | 30 seconds |
Weight | 86 grams |
Packing unit in pcs | 20 per plastic tray / 100 per carton box |
绕组
Power | |
At Pickup Voltage | 925mw.DCcoil |
(typical) | 2.6VA AC coil |
Max. Continuous | 5.0Wat20°C(68F)ambient DC oo |
Dissipation | 7.0VA at 20°C(68°F)ambient AC coil |
Temperature Rise | 48C86°Fatnominal coilvoltage,DCcoil 68C(122F)atnominal coi voltage,AC coil |
Temperature | Max. 155°C (311°F) |
Notes: 1. All values at 20°C (68°F). 2. Relay may pull in with less than “Must Operate” value. 3. Specifications subject to change without notice. |
继电器订购数据
COIL SPECIFICATIONS – DC Coil | ORDER NUMBER* | ||||
Nominal Coil VDC | Must Operate VDC | Max. Continuous VDC | Nominal Current mA ± 10% | Coil Resistance Ohm ± 10% | |
5 | 3.8 | 8.0 | 326.7 | 15.3 | PR60–2C–5D |
6 | 4.5 | 10.5 | 272.0 | 22 | PR60–2C–6D |
12 | 9.0 | 20.7 | 140.0 | 86 | PR60–2C–12D |
24 | 18.0 | 41.8 | 68.5 | 350 | PR60–2C–24D |
78 | 36.0 | 83.4 | 34.5 | 1390 | PR60–2C–48D |
110 | 82.5 | 190.5 | 15.2 | 7255 | PR60–2C–110D |
COIL SPECIFICATIONS – AC Coil | ORDER NUMBER* | |||||
Nominal Coil VDC | Must Operate VDC | Max. Continuous VDC | Nominal Current mA ± 10% | 50Hz Coil Resistance Ohm ± 10% | 60Hz Coil Resistance Ohm ± 10% | |
12 | 9.6 | 15.6 | 340.0 | 9.5 | 8 | PR60–2C–12A6 |
24 | 19.2 | 31.2 | 166.0 | 45 | 35.7 | PR60–2C–24A6 |
120 | 96.0 | 156.0 | 33.3 | 1125 | 830 | PR60–2C–120A6 |
220 | 176.0 | 286.0 | 18.2 | 3800 | 2870 | PR60–2C–220A6 |
240 | 192.0 | 312.0 | 16.7 | 4500 | 3800 | PR60–2C–240A6 |
277 | 221.6 | 360.1 | 14.4 | 5960 | 4700 | PR60–2C–277A6 |
- 用 “2A “代替 “2C”,表示2个A型联系人。
- “2A “或 “2C “表示银镉触点。
- 在 “2A “或 “2C “中加入后缀 “E”,用于银锡氧化物触点。
- 对于50Hz的线圈,只需添加后缀 “5 “的交流线圈。 (例如:PR60-2C-24A5)。
- 50/60Hz的线圈加后缀 “6”,只适用于交流线圈。 (例如:PR60-2C-24A6)。
- 如果是密封版本,请在订单号后面加上后缀 “E”。
- 对于0.187″ x 0.020″ (4.8mm x 0.5mm)线圈终端,添加后缀 “K”。